Related Experiment Video
Updated: Feb 24, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Distance-dependent accuracy in Le Fort I maxillary repositioning procedures
T Dreiseidler1, L Ritter2, M Zirk1
1Dept. of Craniomaxillofacial and Plastic Surgery, University of Cologne, Germany.
Maxillary repositioning accuracy decreases with longer surgical movements, especially in the sagittal plane. This study confirms that greater distances moved during Le Fort I osteotomies lead to less precise outcomes.
Area of Science:
- Oral and Maxillofacial Surgery
- Orthognathic Surgery
- Biomedical Engineering
Background:
- Maxillary repositioning procedures aim for precise skeletal movements.
- The influence of repositioning distance on surgical accuracy remains under-investigated.
Purpose of the Study:
- To evaluate the correlation between planned maxillary repositioning distances and achieved accuracy.
- To identify planes and anatomical landmarks most affected by repositioning distance.
Main Methods:
- Analysis of Cone-beam CT scans from 92 patients undergoing Le Fort I osteotomies.
- Measurement of maxillary displacement in axial, sagittal, and transverse planes.
- Statistical analysis using Pearson's correlation coefficient to compare planned vs. achieved movements.
Main Results:
- Significant correlations between planned distance and achieved accuracy were found, particularly in the sagittal plane at the first molar landmarks (M1L and M1R).
- Accuracy decreased as the planned repositioning distance increased, with observed errors up to 12mm for planned movements of 0-4mm.
- The sagittal plane showed the weakest correlation, indicating greater potential for error in this dimension.
Conclusions:
- Surgical accuracy in wafer-based maxillary repositioning is distance-dependent.
- Longer repositioning distances are associated with reduced accuracy, especially in the sagittal plane and affecting molar regions.