Introduction:
Contemporary dogma has classically attributed hand dysfunction following hemodialysis arteriovenous fistula (AVF) placement to regional ischemia. We hypothesize that hemodynamic perturbations alone do not entirely explain the postoperative changes in hand function and, furthermore, that various elements of hand function are differentially affected following surgery.
Methods:
Bilateral wrist and digital pressures and upper extremity nerve conduction tests were recorded preoperatively and at 6 weeks and 6 months following upper extremity AVF construction in 46 patients. Concurrently, biomechanical tests were administered to evaluate multiple limb functional domains including grip strength, dexterity, sensation and perception of hand function.
Results:
Mean age was 59±14 years (75% male) and 48% were on hemodialysis at the time of access placement. 69% had a brachial-based AVF, and the remainder had radial-based accesses. Six weeks following AVF placement, a significant decrease in access side digital pressures was observed, with only partial recovery at 6 months (P<0.0001). Grip strength was significantly worse in the access side limb (P=0.0003), and Disability of Arm, Shoulder and Hand Questionnaire (DASH) score substantially worsened postoperatively (P=0.06). Digital sensation and limb dexterity did not differ between limb sides (P>0.1) or change significantly over time (P>0.1). Principal component analyses demonstrated that nerve conduction parameters tended to track the biomechanical parameters, yet both were relatively independent of the hemodynamic parameters.
Conclusion:
Our findings suggest that ischemia alone does not completely explain access-related hand dysfunction and that future study is needed to elucidate alternative mechanisms.
More Related Videos
07:30Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Related Concept Videos
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Hemodialysis III: Nursing Management
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...