Related Concept Videos

Cryo-electron Microscopy01:28

Cryo-electron Microscopy

4.4K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
4.4K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

3.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.0K
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

1.1K
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Lattice-Directed Spin-Vibronic Coherence-Mediated Ultrafast Intersystem Crossing in Crystalline Diplatinum Complex.

Journal of the American Chemical Society·2026
Same author

Enhancing IR-MALDESI MSI Spatial Resolution Through Beam Constriction With a Ring-Actuated Iris.

Rapid communications in mass spectrometry : RCM·2026
Same author

High-Throughput N-Glycan Analysis by IR-MALDESI With a 1.5-kHz Pulsed Mid-IR Laser.

Journal of mass spectrometry : JMS·2026
Same author

Vibronic and Spin-Orbit Interplay Governs Ultrafast Spin Crossover in an Iron(II) Carbene Complex.

Chemphyschem : a European journal of chemical physics and physical chemistry·2026
Same author

Elucidating the Transition Kernel and Anharmonic Coupling in the Spin-crossover Process of a [Fe<sup>III</sup>(qsal)<sub>2</sub>] CH<sub>3</sub>OSO<sub>3</sub> Complex.

Angewandte Chemie (International ed. in English)·2026
Same author

Room-temperature structure determination of vacuum-sensitive organic compounds by formvar encapsulation and serial electron diffraction.

Journal of applied crystallography·2026

Related Experiment Video

Updated: Feb 23, 2026

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
08:16

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

Published on: March 19, 2021

5.0K

Low-dose cryo electron ptychography via non-convex Bayesian optimization.

Philipp Michael Pelz1,2, Wen Xuan Qiu3, Robert Bücker4

  • 1Max Planck Institute for the Structure and Dynamics of Matter, Center for Free Electron Laser Science, Luruper Chaussee 149, 22761, Hamburg, Germany. philipp.pelz@mpsd.mpg.de.

Scientific Reports
|August 31, 2017
PubMed
Summary
This summary is machine-generated.

We developed a new low-dose electron ptychography method using Bayesian optimization. This technique significantly reduces radiation dose, enabling high-resolution imaging of sensitive biological samples like macromolecules.

More Related Videos

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

6.0K
Author Spotlight: Optimizing Grid Preparation for Enhanced Cryoelectron Tomography
08:17

Author Spotlight: Optimizing Grid Preparation for Enhanced Cryoelectron Tomography

Published on: December 15, 2023

3.8K

Related Experiment Videos

Last Updated: Feb 23, 2026

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
08:16

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

Published on: March 19, 2021

5.0K
Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

6.0K
Author Spotlight: Optimizing Grid Preparation for Enhanced Cryoelectron Tomography
08:17

Author Spotlight: Optimizing Grid Preparation for Enhanced Cryoelectron Tomography

Published on: December 15, 2023

3.8K

Area of Science:

  • Microscopy
  • Biophysics
  • Computational Imaging

Background:

  • Electron ptychography offers atomic resolution phase-sensitive imaging.
  • High radiation doses limit its application to radiation-hard samples, excluding biological specimens.

Purpose of the Study:

  • To reduce the radiation dose required for electron ptychography.
  • To enable high-resolution imaging of biological samples, particularly single macromolecules.

Main Methods:

  • Utilized non-convex Bayesian optimization for dose reduction in electron ptychography.
  • Performed numerical simulations to validate the proposed method.

Main Results:

  • Reduced required dose by two orders of magnitude compared to previous methods.
  • Achieved 2D single-particle reconstructions of simulated macromolecules at 5.4 Å resolution with 20e-/Ų dose.
  • Demonstrated potential for ~3.5 Å resolution with 30 low-dose datasets for complexes <100 kDa.

Conclusions:

  • Non-convex Bayesian optimization significantly lowers radiation dose for electron ptychography.
  • Low-dose cryo electron ptychography is a promising technique for imaging single biological macromolecules.
  • This method offers advantages over traditional phase-contrast microscopy for biological imaging.