Optical coherence tomography image denoising using Gaussianization transform
Related Experiment Video
Updated: Feb 23, 2026

Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters
Published on: June 2, 2010
Abstract:
We demonstrate the power of the Gaussianization transform (GT) for modeling image content by applying GT for optical coherence tomography (OCT) denoising. The proposed method is a developed version of the spatially constrained Gaussian mixture model (SC-GMM) method, which assumes that each cluster of similar patches in an image has a Gaussian distribution. SC-GMM tries to find some clusters of similar patches in the image using a spatially constrained patch clustering and then denoise each cluster by the Wiener filter. Although in this method GMM distribution is assumed for the noisy image, holding this assumption on a dataset is not investigated. We illustrate that making a Gaussian assumption on a noisy dataset has a significant effect on denoising results. For this purpose, a suitable distribution for OCT images is first obtained and then GT is employed to map this original distribution of OCT images to a GMM distribution. Then, this Gaussianized image is used as the input of the SC-GMM algorithm. This method, which is a combination of GT and SC-GMM, remarkably improves the results of OCT denoising compared with earlier version of SC-GMM and even produces better visual and numerical results than the state-of-the art works in this field. Indeed, the main advantage of the proposed OCT despeckling method is texture preservation, which is important for main image processing tasks like OCT inter- and intraretinal layer analysis. Thus, to prove the efficacy of the proposed method for this analysis, an improvement in the segmentation of intraretinal layers using the proposed method as a preprocessing step is investigated. Furthermore, the proposed method can achieve the best expert ranking between other contending methods, and the results show the helpfulness and usefulness of the proposed method in clinical applications.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Imaging Studies III: Computed Tomography
Gaussian Elimination: Problem Solving
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....