Assessment of the cardiac output (CO) is usually performed with invasive techniques requiring specialized equipment in the intensive care unit (ICU). With TEL-O-GRAPH (TG), CO can be derived from the oscillometrically obtained brachial pulse wave during the measurement of brachial blood pressure. CO and stroke volume (SV) determinations with TG were compared with transpulmonary thermodilution measurements with the PICCO system (PICCO) in 38 haemodynamically unstable ICU patients with a total of 84 comparison measurements performed. SV (33.3 ± 9.0 ml/m2 vs. 44.3 ± 14.4 ml/m2, p < 0.001) and CO (2.7 ± 0.5 l/min/m2 vs. 3.8 ± 1.2 l/min/m2, p < 0.001) were underestimated significantly with TG and oscillometric brachial systolic blood pressure (BP) was significantly lower and diastolic BP significantly higher than invasive femoral artery pressure. A linear correlation was found between CO dimension and CO underestimation with TG. Correct tracking of CO changes with a fluid challenge was possible in 69.5% of measurements. Oscillometric noninvasive CO is possible in the ICU, but accuracy and precision of this new method are lacking. Implementation of a correction factor accounting for the linear increase in CO underestimation observed with increasing CO could improve CO assessment with TG in haemodynamically unstable patients.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...