Related Experiment Video
Updated: Feb 23, 2026

Psychophysically-anchored, Robust Thresholding in Studying Pain-related Lateralization of Oscillatory Prestimulus Activity
Published on: January 21, 2017
Rethinking Residue: Determining the Perceptual Continuum of Residue on FEES to Enable Better Measurement
Jessica M Pisegna1,2, Asako Kaneoka3, Rebecca Leonard4
1Boston Medical Center, FGH Building 820 Harrison Ave, Boston, MA, 02118, USA. jpisegna@bu.edu.
Abstract:
The goal of this work was to better understand perceptual judgments of pharyngeal residue on flexible endoscopic evaluation of swallowing (FEES) and the influence of a visual analog scale (VAS) versus an ordinal scale on clinician ratings. The intent was to determine if perceptual judgments of residue were more accurately described by equal or unequal intervals. Thirty-three speech language pathologists rated pharyngeal residue from 75 FEES videos representing a wide range of residue severities for thin liquid, applesauce, and cracker boluses. Clinicians rated their impression of the overall residue amount in each video on a VAS and, in a different session, on a five-point ordinal scale. Residue ratings were made in two separate sessions separated by several weeks. Statistical correlations of the two rating methods were carried out and best-fit models were determined for each bolus type. A total of 2475 VAS ratings and 2473 ordinal ratings were collected. Residue ratings from both methods (VAS and ordinal) were strongly correlated for all bolus types. The best fit for the data was a quadratic model representing unequal intervals, which significantly improved the r 2 values for each bolus type (cracker r 2 = 0.98, applesauce r 2 = 0.99, thin liquid r 2 = 0.98, all p < 0.0001). Perceptual ratings of pharyngeal residue demonstrated a statistical relationship consistent with unequal intervals. The present findings support the use of a VAS to rate residue on FEES, allowing for greater precision as compared to traditional ordinal rating scales. Perceptual judgments of pharyngeal residue reflected unequal intervals, an important concept that should be considered in future rating scales.
Related Concept Videos
Sensation
Absolute thresholds can quantify the sensitivity of sensory...
Mass Analyzers: Overview
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
¹H NMR Signal Integration: Overview
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Perceptual Constancy
Size constancy is the recognition that an object remains the same size, even when its image on the retina changes. For instance, a bus is perceived to be large enough to carry people, even if it looks tiny from...

