[ERCP procedures as a source of radiation risk to a single gastroenterologist]
Maria A Staniszewska1, Krzysztof Kujawski2, Renata Kopeć3
1Uniwersytet Medyczny w Łodzi / Medical University of Lodz, Łódź, Poland (Wydział Nauk Biomedycznych i Kształcenia Podyplomowego, Zakład Medycznych Technik Obrazowania / Faculty of Biomedical Sciences and Postgraduate Education, Department of Medical Imaging Techniques). maria.staniszewska@umed.lodz.pl.
Background:
One of the numerous sub-areas of interventional radiology is the use of X-rays in gastroenterology. X-ray fluoroscopy is applied in therapeutic procedures, including endoscopic retrograde cholangiopancreatography (ERCP) that is frequently performed. The ERCP procedure is aimed at imaging the pancreatic duct and biliary tracts.
Material And Methods:
In this paper radiation risk to the gastrenterologist performing ERCP procedures was investigated. The procedures were performed by a single gastroenterologist in the ERCP Laboratory, University Clinical Hospital Military Memorial Medical Academy - Central Veterans' Hospital in Łódź, Poland. The study comprised 2 series of measurements, one taken during the procedures with continuous fluoroscopy mode, the other during procedures with fluoroscopy in pulsed mode at a frequency of 3 pulses/s. Exposure parameters, anatomical data of patient and dose equivalents for the eyes, skin of the hand and the effective dose for whole body of the gastroenterologist were recorded during each procedure.
Results:
The collected data cover 70 ERCP procedures - 40 procedures were controlled by continuous fluoroscopy and 30 by pulsed fluoroscopy. The results reveal that pulsed fluoroscopy makes it possible to reduce doses received by the gastroeneterologist from 45% to 60% compared to continuous fluoroscopy.
Conclusions:
Endoscopic retrograde cholangiopancreatography procedures can cause radiation risk to the gastroenterologist performing them. The use of continuous fluoroscopy can result in achieving an equivalent dose to eye lens nearly 20 mSv per year, i.e., the decreased annual limit recommended by the International Commission on Radiological Protection (ICRP). Med Pr 2017;68(6):735-741.
Related Concept Videos
Endoscopic Procedures V: ERCP
Patient...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...