Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Ultrasound carpal tunnel syndrome: additional criteria for diagnosis
A W H Ng1, J F Griffith1, R K L Lee1
1Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong.
Aim:
To define the usefulness of the cross-sectional area (CSA) of the median nerve distal to the carpal tunnel in addition to other established common parameters in the diagnosis of carpal tunnel syndrome (CTS).
Materials And Methods:
Forty-four wrists from 24 symptomatic CTS patients and 32 wrists from 17 asymptomatic volunteers were evaluated by ultrasound. The CSA of the median nerve was measured at four pre-selected levels, i.e., proximal, inlet, outlet, and distal to the carpal tunnel. The flattening ratio, intraneural vascularity, neural fasciculation, and retinacular palmar bowing were also assessed.
Results:
Significant differences were found between the CTS and control groups for median nerve CSA proximal and distal (p<0.001) to the tunnel as well as retinacular bowing (p<0.001). Using the receiver operating characteristic (ROC) curve, the sensitivity, specificity, and accuracy of using a cut-off of >14 mm2 of CSA proximal and distal to the tunnel were 75%, 87.5%, 86.8% and 63.6%, 100%, 78.9%, respectively. Using either CSA proximal or distal to the tunnel or bowing retinaculum at the outlet >1 mm yielded a sensitivity, specificity, and accuracy of 100%, 84.3% and 93.4%, respectively.
Conclusion:
The median nerve CSA proximal and distal to the carpal tunnel and bowing of the retinaculum at the outlet are helpful in diagnosis of CTS.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Ultrasonography
During an ultrasonography procedure, a handheld device called...