Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Critical Numbers and the Closed Interval Method01:21

Critical Numbers and the Closed Interval Method

99
Understanding the maximum and minimum values of a function is essential for analyzing its overall behavior. These values, often referred to as extrema, provide insight into how a function behaves across its domain. In mathematical terms, extrema can be either local—representing peaks and valleys within a limited region—or absolute, indicating the highest or lowest points over an entire interval.A function’s extrema occur at critical numbers, which are values in the domain...
99
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

1.3K
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
1.3K
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

7.1K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.1K
Prediction Intervals01:03

Prediction Intervals

3.5K
The interval estimate of any variable is known as the prediction interval. It helps decide if a point estimate is dependable.
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y. 
3.5K
Interval Level of Measurement00:55

Interval Level of Measurement

19.6K
For effective statistical analysis, data are classified into four levels of measurement—nominal, ordinal, interval, and ratio.
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
19.6K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

1.8K
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Symptom severity assessment in patients with atrial fibrillation after catheter ablation using a smartphone application.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2026
Same author

Pre-procedural time spent in atrial fibrillation using intermittent ECG monitoring is associated with arrhythmia recurrence after ablation: the ISOLATION cohort study.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2026
Same author

Ablation of atrial fibrillation sources identified through sequential high-density mapping: in silico comparison against anatomy-based approaches.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2025
Same author

Spontaneous coronary artery dissection: dissecting an underdiagnosed problem.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2025
Same author

Prevalence of Patent Foramen Ovale in Patients with Non-Obstructive Coronary Artery Disease (PROVA) Study.

Journal of cardiovascular development and disease·2025
Same author

Time-dependent repolarization changes following left bundle branch area pacing vs. conventional biventricular pacing in patients with dyssynchronous heart failure.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2025

Related Experiment Video

Updated: Feb 23, 2026

Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
06:07

Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice

Published on: May 23, 2021

4.4K

The development and validation of an easy to use automatic QT-interval algorithm.

Ben J M Hermans1,2,3, Arja S Vink4, Frank C Bennis1,5

  • 1Department of Biomedical Engineering, Maastricht University, Maastricht, The Netherlands.

Plos One
|September 2, 2017
PubMed
Summary

This study developed an automated algorithm for precise beat-to-beat QT-interval measurements, overcoming challenges like varying heart axis and T-wave shapes for improved drug safety analysis.

More Related Videos

Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
11:13

Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs

Published on: May 12, 2017

20.9K
Iterative Development of an Innovative Smartphone-Based Dietary Assessment Tool: Traqq
04:54

Iterative Development of an Innovative Smartphone-Based Dietary Assessment Tool: Traqq

Published on: March 19, 2021

5.3K

Related Experiment Videos

Last Updated: Feb 23, 2026

Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
06:07

Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice

Published on: May 23, 2021

4.4K
Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
11:13

Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs

Published on: May 12, 2017

20.9K
Iterative Development of an Innovative Smartphone-Based Dietary Assessment Tool: Traqq
04:54

Iterative Development of an Innovative Smartphone-Based Dietary Assessment Tool: Traqq

Published on: March 19, 2021

5.3K

Area of Science:

  • Cardiology
  • Biomedical Engineering
  • Electrocardiography

Background:

  • Beat-to-beat QT-interval measurements are crucial for evaluating cardiac repolarization dynamics and drug safety.
  • Traditional methods face limitations due to interobserver variability, aberrant T-wave morphologies, and heart axis shifts.

Purpose of the Study:

  • To develop and validate a novel algorithm for automated, beat-to-beat QT-interval assessment.
  • The algorithm aims to be robust against variations in heart axis orientation and T-wave morphology.

Main Methods:

  • Utilized standard ECG leads, root mean square (ECGRMS), standard deviation, and vectorcardiogram for analysis.
  • Defined QRS onset from ECGRMS and T-wave end using an automated tangent method across multiple leads.
  • Validated the algorithm on supine-standing tests from 73 Long-QT syndrome patients and 54 controls, comparing automated with manual measurements.

Main Results:

  • Automated QT-interval measurements demonstrated a bias of <4ms and limits of agreement of ±25ms compared to manual measurements.
  • Achieved excellent agreement (intra-class coefficient >0.9) between the algorithm and individual observers, as well as the mean of observer measurements.
  • Excluded 21 complexes from analysis due to noise, flat T-waves, or premature ventricular beats.

Conclusions:

  • The developed automated algorithm provides reliable beat-to-beat QT-interval assessment.
  • The algorithm is robust to variations in heart axis and T-wave morphology, enhancing accuracy in clinical and drug safety evaluations.