Marginal Emission Factors Considering Renewables: A Case Study of the U.S. Midcontinent Independent System Operator

Mo Li1, Timothy M Smith1,2, Yi Yang3

  • 1NorthStar Initiative for Sustainable Enterprise, Institute on the Environment, University of Minnesota , 325 Learning and Environmental Sciences, 1954 Buford Avenue, Saint Paul, Minnesota 55108, United States.

Related Concept Videos

Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
644
Independent and Dependent Sources01:18

Independent and Dependent Sources

In electrical circuits, sources play a crucial role in providing power for the operation of the circuit. These sources can be broadly categorized into two types: independent and dependent.
Independent voltage or current sources supply a fixed amount of voltage or current, respectively, which is unaffected by other elements within the circuit. These are represented using specific symbols. Independent voltage sources are symbolized with polarities (+ and -), indicating the direction of the...
2.7K
Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.7K
Power System Distribution01:25

Power System Distribution

Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
1.1K
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
1.0K
Energy Budgets00:51

Energy Budgets

Organisms must balance energy intake with the energy required for growth, maintenance and reproduction. These trade-offs result in a variety of survivorship and reproductive strategies, including semelparity and iteroparity. Semelparous species, like annual plants, have only one reproductive episode in their lifetimes and consequently have short lifespans. Iteroparous species, by contrast, have many reproductive events during their lifetimes but have relatively few offspring. These two...
11.0K