Related Experiment Video
Updated: Feb 23, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
Hemodynamic analysis of blood flow in umbilical artery using computational modeling
Ruchit G Shah1, Theresa Girardi1, George Merz2
1Placental Analytics, LLC, New Rochelle, NY, USA.
Abstract:
The umbilical cord is the crucial pathway for blood flow between the fetus and the placenta. Umbilical coiling and length have been separately linked to adverse clinical outcomes; however, the effects of variations of these parameters on umbilical arterial blood flow are not well understood. Using 3D computational model, we studied the individual and combined effects of umbilical coiling index, cord length and arterial diameter on umbilical artery hemodynamics. We found that specific combinations of umbilical coiling index, cord length and arterial diameter yielded pressure and flow drops incompatible with fetal life. Such models are useful as hypothesis-developing tools.
Related Concept Videos
Applications of Integration to Find Blood Flow
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....