Related Experiment Video
Updated: Feb 23, 2026

Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
Relationship Between Hemorheology Assessed Using Microchannel Array Flow Analyzer and Kidney Function in Hypertensive
1Hitsumoto Medical Clinic, 2-7-7, Takezakicyou, Shimonoseki City, Yamaguchi 750-0025, Japan.
Background:
Kidney function is known to be closely associated with the pathogenesis of hypertension. In contrast, hemorheology assessed using microchannel array flow analyzer (MC-FAN) has demonstrated the significance of cardiovascular risk factors in recent clinical studies. The present cross-sectional study aimed to clarify the relationship between hemorheology assessed by MC-FAN and kidney function in hypertensive patients from the perspective of primary prevention of cardiovascular events.
Methods:
In total, 453 outpatients undergoing treatment for hypertension (176 men and 277 women; mean age ± standard deviation: 65 ± 13 years) with no history of cardiovascular disease were enrolled. Whole blood passage time (WBPT) was measured using MC-FAN as a marker of hemorheology, and the relationships with various clinical parameters including kidney function were examined.
Results:
A significant correlation was observed between WBPT and the parameters of kidney function such as estimated glomerular filtration rate (r = -0.14, P < 0.01), urinary albumin excretion (r = 0.40, P < 0.001), and renal resistive index (r = 0.44, P < 0.001). Furthermore, multivariate analysis demonstrated urinary albumin excretion, renal resistive index, skin autofluorescence, derivatives of reactive oxygen metabolites, and hematocrit as independent variables for WBPT as a subordinate factor.
Conclusions:
The results of the present study indicate that hemorheology assessed by the MC-FAN is significantly associated with markers of kidney function, such as albuminuria and increased renovascular resistance, in hypertensive patients.
Related Concept Videos
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow
Hypertension and Regulation of Blood Pressure
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate