Related Experiment Video
Updated: Feb 23, 2026

08:45
Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
14.1K
Survival of Direct Posterior Composites With and Without a Bulk Fill Base
C McGuirk1, F Hussain1, B J Millar1
1Kings College, London.
The European Journal of Prosthodontics and Restorative Dentistry
|September 5, 2017
Summary
Direct composite restorations using a bulk-fill base material (SDR) showed similar short-term survival to conventional layering composites. However, SDR-based restorations experienced significantly more tooth fractures, indicating a potential risk.
Area of Science:
- Dental Materials Science
- Clinical Dentistry
- Restorative Dentistry
Background:
- Direct composite restorations are widely used in general dental practice.
- Flowable bulk-fill materials like SDR (Dentsply) are designed to reduce polymerization stress.
- This study audits the clinical performance of SDR as a bulk-fill base material.
Purpose of the Study:
- To compare the survival rates and failure modes of direct composite restorations using SDR bulk-fill base versus conventional layering techniques.
- To evaluate post-operative sensitivity and identify factors influencing restoration failure.
Main Methods:
- A retrospective audit of 125 direct composite restorations placed by a single operator.
- Group G: Conventional layering composite (G-aenial, GC).
- Group S: Bulk-fill base of SDR (Dentsply) covered with G-aenial (GC).
- Data collected included survival, post-operative sensitivity, and mode of failure over a minimum of 24 months.
Main Results:
- Survival rates were comparable: 92.6% for Group S and 93% for Group G.
- Group S restorations showed a significantly higher incidence of tooth fracture (p=0.033).
- Restoration failure in both groups was more likely in larger cavities, with more surfaces involved, and with cuspal coverage.
Conclusions:
- Both techniques demonstrate similar short-term survival rates for direct composite restorations.
- A significantly higher rate of tooth fracture was observed with the SDR bulk-fill base technique.
- Further investigation into the long-term implications and fracture risk associated with SDR is warranted.