Related Experiment Video
Updated: Feb 23, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis
C Rivière1, F Iranpour1, S Harris1
1Department of joint replacement, the MSK Lab, Charing Cross Campus, Laboratory Block, Fulham Palace Rd, W6 8RP London, UK.
Introduction:
Kinematic alignment (KA) technique is an alternative technique for positioning a TKA, which aims a patient-specific implant positioning in order to reproduce the pre-arthritic knee anatomy. Because reliability in implant positioning is of interest to obtain reproducible good functional results, our study tests the hypothesis that the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically aligned femoral component are similar.
Methods:
Preoperative knee magnetic resonance imaging (MRI) and postoperative knee computed tomography (CT) of 13 patients implanted with a KA Persona® TKA (Zimmer, Warsaw, USA) using manual instrumentation (kinematically-aligned TKA procedure pack®, Zimmer Biomet, Warsaw, USA) were segmented to create 3D femoral models. The kinematic alignment position of the femoral component was planned on the 3D model created from the preoperative MRI. Differences in the positions of the planned and surgically implanted kinematically-aligned femoral component were determined with in-house analysis software.
Results:
The average differences between the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically-aligned femoral component were inferior to 1mm and no statistically significant. In terms of variability, 62% (8/13) of performed implants matched all four positions within 1.5mm, and the maximum difference was 3mm.
Conclusion:
In this small series, intraoperative kinematic positioning of the femoral component with the specific manual instrumentation closely matched the planned position, which suggests that this technique reliably aligned the flexion-extension axis of the femoral component to the cylindrical axis.
Level Of Evidence:
Level 3.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Related Concept Videos
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bones of the Lower Limb: Femur and Patella