Related Experiment Video
Updated: Feb 23, 2026

Comprehensive & Cost Effective Laboratory Monitoring of HIV/AIDS: an African Role Model
Published on: October 31, 2010
Misdiagnosis of HIV infection during a South African community-based survey: implications for rapid HIV testing
Tendesayi Kufa1,2, Ayesha Bm Kharsany3, Cherie Cawood4
1Centre for HIV and STIs, National Institutes of Communicable Diseases, Sandringham, South Africa.
Introduction:
We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes.
Methods:
Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined.
Results:
Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19-31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5-99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5-93.7), 99.9% (95% CI 99.8-100), 99.3% (95% CI 97.4-99.8) and 99.1% (95% CI 98.8-99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01-0.24) and 8.9% (95% CI 6.3-12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use.
Conclusions:
The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes.
More Related Videos
19:57An Affordable HIV-1 Drug Resistance Monitoring Method for Resource Limited Settings
Published on: March 30, 2014
13:58Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011