Spatial variance of POPs and heavy metals in transformer oil-contaminated soil around Tamil Nadu
Karuvelan Murugan1, Namasivayam Vasudevan2
1Centre for Environmental Studies, Anna University, CEG Campus, Chennai, Tamil Nadu, India.
Abstract:
The persistent organic pollutants in the environment are one of the global issues to their unregulated disposal and informal recycling. This study investigates the contamination of soil with polychlorinated biphenyls (PCBs), polyaromatic hydrocarbons (PAHs), phenolic compounds and heavy metals via spillage of transformer oil (TO). Fresh TO (FTO), used TO (UTO) and soil samples were analysed using GC-MS to confirm the presence of 8 PCB congeners, 16 PAHs and 24 types of phenolic compounds and using inductively coupled plasma optical emission spectrometry to confirm the presence of 7 heavy metals. The chromatographic analysis revealed the levels of mono-, di-, tri-, tetra-, penta-, hexa-, hepta- and octachlorobiphenyls in FTO to be 5.63, 25.24, 0.195, 0.185, 2.169, 1.023 and 5.28 mg/L and the level of mono-, di-, tri-, tetra-, penta- and hexachlorobiphenyls in UTO to be 0.27, 1.21, 1.31, 0.80, 1.77 and 3.90 mg/L. Analysis of soil from 10 different TO-contaminated sites showed the presence of PCBs, PAHs, phenolic compounds and heavy metals in the concentration range of 0.53-42.87 mg/kg, 3.19-246.6 μg/kg, 0.01-4086.45 μg/kg and 1.0-401.3 mg/kg, respectively. The variation in the concentration of these compounds and heavy metals among different sampling sites was determined using principal component analysis (PCA), metric multi-dimensional scaling (MDS) and Bray-Curtis cluster analysis (Bu-CA). The toxicity equivalence factor and the mechanism involved in the disruption of endocrine system are discussed. Thus, this study exemplifies the need for complete ban of PCB-containing TOs in developing countries and urges the need for technology for the disposal of TO.
More Related Videos
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Types of Toxins
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
Instrument Transformers
Equivalent Circuits for Practical Transformers