Related Experiment Video
Updated: Feb 23, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Identifying the more suitable nostril for nasotracheal intubation using radiographs
Seong In Chi1, Sookyung Park1, Li-Ah Joo1
1Department of Dental Anesthesiology, School of Dentistry, Seoul National University, Seoul, Korea.
Background:
One nostril must be selected for nasotracheal intubation. In some cases, structural anomalies within the nasal cavity hinder the insertion of the tube or complications, such as epistaxis, develop. This study examined the possibility of using radiography to select the nostril that would induce fewer complications.
Methods:
Four hundred and five patients who underwent nasotracheal intubation under general anesthesia were studied. A 7.0-mm internal diameter nasal right angle endotracheal (RAE) tube and 6.5-mm internal diameter nasal RAE tube were inserted into men and women, respectively. Complications were considered to have developed in cases in which insertion of the tube into the nasal cavity failed or epistaxis occurred. The tube was inserted into the other nostril for insertion failures and hemostasis was performed in cases of epistaxis. The degree of nasal septal deviation was determined from posteroanterior skull radiographs or panoramic radiographs; the incidence of complications was compared depending on the direction of the septal deviation and the intubated nostril.
Results:
The radiographs of 390 patients were readable; 94 had nasal septum deviation. The incidence of complications for cases without nasal septum deviation was 16.9%, that for cases in which the tube was inserted into the nostril on the opposite side of the deviation was 18.5%, and that for cases in which the tube was inserted into the nostril with the deviation was 35.0%, showing a high incidence of complications when intubation is performed through the nostril with septum deviation (chi-square test, P < 0.05 ).
Conclusions:
Although there were no differences in the incidence rates of complications between intubation through the left nostril and that through the right nostril, radiological findings indicated that incidence of complications significantly increased when the tube was inserted into the nostril with the septum deviation.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Suctioning the Nasopharyngeal Airway
Equipment Required

