Theoretical and experimental comparison of lag-based and time-based exponential moving average models of QT
Vincent Jacquemet1,2, Hugo Gravel3, Daniel Curnier3,4
1Département de Pharmacologie et Physiologie, Institut de Génie Biomédical, Université de Montréal, Montréal, Canada.
Objective:
In the electrocardiogram, adaptation of the QT interval to variations in heart rate is not instantaneous. Quantification of this hysteresis phenomenon relies on mathematical models describing the relation between the RR and QT time series. These models reproduce hysteresis through an effective RR interval computed as a linear combination of the history of past RR intervals. This filter depends on a time constant parameter that may be used as a biomarker.
Approach:
The most common hysteresis model is based on an autoregressive filter with an impulse response that decreases exponentially with the beat number (lag-based model). Recognizing that the QT time series is unevenly spaced, we propose two exponential moving average filters (time-based models) to define the effective RR interval: one with an impulse response that decreases exponentially with time in seconds, and one with a step response that relaxes exponentially with time in seconds. These two filters are neither linear nor time-invariant. Recurrence formulas are derived to enable efficient implementation.
Main Results:
Application to clinical signals recorded during tilt table test, exercise and 24 h Holter demonstrates that the three models perform similarly in terms of goodness-of-fit. When comparing the hysteresis time constant in two conditions with different heart rates, however, the time-based models are shown to reduce the bias on the hysteresis time constant caused by heart rate acceleration and deceleration.
Significance:
Time-based models should be considered when intergroup differences in both heart rate and QT hysteresis are expected.
More Related Videos
07:41Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
Published on: June 5, 2017
07:59Author Spotlight: Alignment of Synchronized Time-Series Data Using the Characterizing Loss of Cell Cycle Synchrony Model for Cross-Experiment Comparisons
Published on: June 9, 2023
Related Concept Videos
Detection of Gross Error: The Q Test
Parametric Survival Analysis: Weibull and Exponential Methods
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Pharmacodynamic Models: Link Model and Systems Pharmacodynamic Model
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...