Technical Considerations on Phase Mapping for Identification of Atrial Reentrant Activity in Direct- and
Miguel Rodrigo1, Andreu M Climent1, Alejandro Liberos1
1From the ITACA Institute, Universitat Politècnica de València, Spain (M.R., M.S.G.); CIBERCV, Hospital General Universitario Gregorio Marañón, Instituto de investigación sanitaria Gregorio Marañón, Madrid, Spain (A.M.C., A.L., F.F.-A., F.A.); Facultad de Medicina, Universidad Complutense de Madrid, Spain (F.F.-A., F.A.); and Center for Arrhythmia Research, University of Michigan, Ann Arbor (O.B.).
Background:
Phase mapping has become a broadly used technique to identify atrial reentrant circuits for ablative therapy guidance. This work studies the phase mapping process and how the signal nature and its filtering affect the reentrant pattern characterization in electrogram (EGM), body surface potential mapping, and electrocardiographic imaging signals.
Methods And Results:
EGM, body surface potential mapping, and electrocardiographic imaging phase maps were obtained from 17 simulations of atrial fibrillation, atrial flutter, and focal atrial tachycardia. Reentrant activity was identified by singularity point recognition in raw signals and in signals after narrow band-pass filtering at the highest dominant frequency (HDF). Reentrant activity was dominantly present in the EGM recordings only for atrial fibrillation and some atrial flutter propagations patterns, and HDF filtering allowed increasing the reentrant activity detection from 60% to 70% of time in atrial fibrillation in unipolar recordings and from 0% to 62% in bipolar. In body surface potential mapping maps, HDF filtering increased from 10% to 90% the sensitivity, although provoked a residual false reentrant activity ≈30% of time. In electrocardiographic imaging, HDF filtering allowed to increase ≤100% the time with detected rotors, although provoked the apparition of false rotors during 100% of time. Nevertheless, raw electrocardiographic imaging phase maps presented reentrant activity just in atrial fibrillation recordings accounting for ≈80% of time.
Conclusions:
Rotor identification is accurate and sensitive and does not require additional signal processing in measured or noninvasively computed unipolar EGMs. Bipolar EGMs and body surface potential mapping do require HDF filtering to detect rotors at the expense of a decreased specificity.
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...