Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and
Hans-Jonas Meyer1,2, Oliver Ziemann1, Malte Kornhuber3
11 Department of Diagnostic Radiology, Martin-Luther University Halle-Wittenberg, Halle, Germany.
Magnetic resonance imaging (MRI) using diffusion-weighted imaging (DWI) revealed higher apparent diffusion coefficient (ADC) values in muscles affected by myositis and non-inflammatory myopathies compared to healthy muscles. No significant correlations were found between ADC values and laboratory markers.
Area of Science:
- Medical Imaging
- Neurology
- Musculoskeletal Disorders
Background:
- Magnetic resonance imaging (MRI) is crucial for diagnosing muscle disorders.
- Diffusion-weighted imaging (DWI) provides insights into tissue microstructure.
- The apparent diffusion coefficient (ADC) quantifies water molecule diffusion, reflecting tissue characteristics.
Purpose of the Study:
- To investigate apparent diffusion coefficient (ADC) values in patients with myositis and non-inflammatory myopathy.
- To analyze potential associations between ADC values and laboratory parameters in these patient groups.
Main Methods:
- Seventeen patients with myositis, eight with non-inflammatory myopathies, and nine controls underwent 1.5-T DWI.
- Histopathology confirmed diagnoses.
- Blood samples for laboratory parameters were collected within three days of MRI.
Main Results:
- Mean ADC values were significantly higher in affected muscles (myositis: 1.89×10⁻³ mm²/s; non-inflammatory myopathy: 1.79×10⁻³ mm²/s) compared to unaffected muscles (1.15×10⁻³ mm²/s).
- No significant correlations were identified between ADC values and serological parameters (CRP, LDH, ALT, AST, CK, myoglobin).
Conclusions:
- Affected muscles in myositis and non-inflammatory myopathies exhibit significantly elevated ADC values.
- ADC values do not show linear correlations with the assessed laboratory parameters in these conditions.
More Related Videos
05:25Author Spotlight: Expanding the Scope of Multiplex Immunoassays for Lyme Borreliosis Diagnostics and Pathogen Research
Published on: July 14, 2023
12:06Molecular Diffusion in Plasma Membranes of Primary Lymphocytes Measured by Fluorescence Correlation Spectroscopy
Published on: February 1, 2017
Related Concept Videos
Protein Diffusion in the Membrane
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...