Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and
Hans-Jonas Meyer1,2, Oliver Ziemann1, Malte Kornhuber3
11 Department of Diagnostic Radiology, Martin-Luther University Halle-Wittenberg, Halle, Germany.
Abstract:
Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm2. In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10-3 mm2/s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10-3 mm2/s, respectively. The mean ADC values (1.15 ± 0.37 × 10-3 mm2/s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.
Insights
Magnetic resonance imaging (MRI) using diffusion-weighted imaging (DWI) revealed higher apparent diffusion coefficient (ADC) values in muscles affected by myositis and non-inflammatory myopathies compared to healthy muscles. No significant correlations were found between ADC values and laboratory markers.
Area of Science:
- Medical Imaging
- Neurology
- Musculoskeletal Disorders
Background:
- Magnetic resonance imaging (MRI) is crucial for diagnosing muscle disorders.
- Diffusion-weighted imaging (DWI) provides insights into tissue microstructure.
- The apparent diffusion coefficient (ADC) quantifies water molecule diffusion, reflecting tissue characteristics.
Purpose of the Study:
- To investigate apparent diffusion coefficient (ADC) values in patients with myositis and non-inflammatory myopathy.
- To analyze potential associations between ADC values and laboratory parameters in these patient groups.
Main Methods:
- Seventeen patients with myositis, eight with non-inflammatory myopathies, and nine controls underwent 1.5-T DWI.
- Histopathology confirmed diagnoses.
- Blood samples for laboratory parameters were collected within three days of MRI.
Main Results:
- Mean ADC values were significantly higher in affected muscles (myositis: 1.89×10⁻³ mm²/s; non-inflammatory myopathy: 1.79×10⁻³ mm²/s) compared to unaffected muscles (1.15×10⁻³ mm²/s).
- No significant correlations were identified between ADC values and serological parameters (CRP, LDH, ALT, AST, CK, myoglobin).
Conclusions:
- Affected muscles in myositis and non-inflammatory myopathies exhibit significantly elevated ADC values.
- ADC values do not show linear correlations with the assessed laboratory parameters in these conditions.
More Related Videos
05:25Author Spotlight: Expanding the Scope of Multiplex Immunoassays for Lyme Borreliosis Diagnostics and Pathogen Research
Published on: July 14, 2023
12:06Molecular Diffusion in Plasma Membranes of Primary Lymphocytes Measured by Fluorescence Correlation Spectroscopy
Published on: February 1, 2017
Related Concept Videos
Protein Diffusion in the Membrane
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...