Related Experiment Video
Updated: Feb 23, 2026

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Validity and Reliability of the Stages Cycling Power Meter
Cyril Granier1,2, Christophe Hausswirth1,3, Sylvain Dorel4
1Laboratory of Sport, Expertise and Performance (INSEP), French Institute of Sport, Expertise and Performance, Paris, France.
Abstract:
Granier, C, Hausswirth, C, Dorel, S, and Le Meur, Y. Validity and reliability of the stages cycling power meter. J Strength Cond Res 34(12): 3554-3559, 2020-This study aimed to determine the validity and the reliability of the Stages power meter crank system (Boulder, United States) during several laboratory cycling tasks. Eleven trained subjects completed laboratory cycling trials on an indoor cycle fitted with SRM Professional and Stages systems. The trials consisted of an incremental test at 100 W, 200 W, 300 W, 400 W, and four 7-s sprints. The level of pedaling asymmetry was determined for each cycling intensity during a similar protocol completed on a Lode Excalibur Sport ergometer. The reliability of Stages and SRM power meters was compared by repeating the incremental test during a test-retest protocol on a Cyclus 2 ergometer. Over power ranges of 100-1,250 W, the Stages system produced trivial to small differences compared with the SRM (standardized typical error values of 0.06, 0.24, and 0.08 for the incremental, sprint, and combined trials, respectively). A large correlation was reported between the difference in power output (PO) between the 2 systems and the level of pedaling asymmetry (r = 0.58, p < 0.001). Recalculating PO of the Stages system according to the level of pedaling asymmetry provided only marginal improvements in PO measures. The reliability of the Stages power meter at the submaximal intensities was similar to the SRM Professional model (coefficient of variation: 2.1 and 1.3% for Stages and SRM, respectively). The Stages system is a suitable device for PO measurements, except when a typical error of measurement <3.0% over power ranges of 100-1,250 W is expected.
More Related Videos
06:00Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test
Published on: July 27, 2015
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Reliability and Validity
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by: