Related Experiment Video
Updated: Feb 23, 2026

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
Confluent Endpoint Subthreshold Argon Laser for Serous Macular Detachment in Tilted Disc Syndrome Refractory to
Abstract:
A 70-year-old woman presented with 20/200 visual acuity in the right eye. Multimodal imaging revealed tilted disc syndrome (TDS) with macular serous detachment (MSD) and pigmentary changes at the temporal margin of the optic disc. Subretinal fluid persisted after three monthly intravitreal bevacizumab (Avastin; Genentech, South San Francisco, CA) injections and threshold focal laser photocoagulation. Subsequently, confluent subthreshold argon laser was applied over the entire area of retinal pigment epithelium (RPE) abnormalities, resulting in the resolution of subretinal fluid without recurrence through 3 years of follow-up. Subthreshold argon laser treatment may serve as a therapeutic option for MSD in TDS. Targeting leakage sites and stimulating RPE cells might help absorb subretinal fluid. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:760-763.].
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...