Investigation on Clarified Fruit Juice Composition by Using Visible Light Micro-Raman Spectroscopy
Carlo Camerlingo1, Flora Zenone2, Ines Delfino3
1Consiglio Nazionale delle Ricerche, Istituto di Cibernetica "E. Caianiello", Pozzuoli, Italy.
Abstract:
Liquid samples of clarified apple and apricot juices at different productionstages were investigated using visible light micro-Raman spectroscopy in order to assessits potential in monitoring fruit juice production. As is well-known, pectin plays a strategicrole in the production of clarified juice and the possibility of using Raman for its detectionduring production was therefore evaluated. The data analysis has enabled the clearidentification of pectin. In particular, Raman spectra of apple juice samples from washedand crushed fruits revealed a peak at 845 cm-1 (typical of pectin) which disappears in theRaman spectra of depectinised samples. The fructose content was also revealed by thepresence of four peaks at 823 cm-1, 872 cm-1, 918 cm-1 and 975 cm-1. In the case of apricotjuice, several Raman fingerprints of β-carotene at 1008, 1159 and 1520 cm-1 were alsohighlighted. Present results resulted interesting for the exclusive use of optical methods forthe quantitative determination of the above-mentioned substances in place of thebiochemical assays generally used for this purpose, which are time consuming and requiredifferent chemical reagents for each of them.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectroscopy: Beer–Lambert Law
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...