Related Experiment Video
Updated: Feb 23, 2026

The Terroir Concept Interpreted through Grape Berry Metabolomics and Transcriptomics
Published on: October 5, 2016
Metalloporphyrin - based Electronic Tongue: an Application for the Analysis of Italian White wines
Giorgio Verrelli1, Larisa Lvova2, Roberto Paolesse3
1Department of Chemical Sciences and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica 1, 00133 Rome, Italy. verrelli@scienze.uniroma2.it.
Abstract:
An Electronic Tongue system (ET) composed of "all-solid-state" potentiometricsensors was developed and applied for the identification of white wines. The sensingproperties were due to the PVC based membranes doped with several metallo-porphyrinsdeposited on the surface of glassy carbon working electrodes; potentiometric responsetowards several ions in a concentration range from 10-5 M to 10-1 M were studied and cross-sensitivity of sensors was estimated. The sensor array was applied both for the classificationand quantitative analysis of "Verdicchio D.O.C." Italian dry white wines produced by ninecantinas. Peculiar parameters of white wines (namely alcoholic degree, volatile acidity, SO₂,L-Malic Acid, L-Lactic Acid and Total Polyphenols) individuated by standard analyticalmethods were compared with the values evaluated by metalloporphyrin-based ET. Thesystem satisfactory discriminates between an artificial wine control and analyzed winescoming from different cantinas and produced in different years. A satisfactory correlationbetween results of wine analysis performed by certified methods and ET response has beenobtained for SO₂, L-Malic Acid, and Total Phenols content. The developed procedureallows the monitoring of the acetic acid amount in wines and hence to control wine volatileacidity, so indicating the initial steps of wine spoilage process.
More Related Videos
08:46Electronic Tongue Generating Continuous Recognition Patterns for Protein Analysis
Published on: September 16, 2014
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Overview