Related Experiment Video
Updated: Feb 23, 2026

A Model of Self-limited Acute Lung Injury by Unilateral Intra-bronchial Acid Instillation
Published on: August 30, 2019
Humidifier Disinfectant-Associated Lung Injury: Six Years after the Tragic Event
Won Young Kim1, Sang Bum Hong2
1Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Abstract:
In 2011, a cluster of peripartum patients were admitted to the intensive care unit of a tertiary hospital in Seoul with signs and symptoms of severe respiratory distress of unknown etiology. Subsequent epidemiological and animal studies suggested that humidifier disinfectant (HD) might represent the source of this pathology. Epidemiological studies, animal studies, and dose-response analysis demonstrated a strong association between HD use and lung injuries. The diagnostic criteria for HD-associated lung injury (HDALI) was defined on the basis of the clinical, pathological, and radiological attributes of the patients. The clinical spectrum of HDALI appears to range from asymptomatic to full-blown acute respiratory failure, and some patients have required actual lung transplantation for survival. The overall mortality of the exposed population was not significant, although peripartum patients and children who were admitted to the intensive care unit did show high mortality rates. Persistent clinical findings such as diffuse ill-defined centrilobular nodules and restrictive lung dysfunction were observed in some of the survivors. The findings of this review emphasize the importance of assessment of the level of toxicity of chemical inhalants utilized in a home setting, as well as the need to identify and monitor afflicted individuals after inhalational injury.
More Related Videos
Related Concept Videos
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-III
Pulmonary Cycle: Exhalation
Pneumonia II: Pathophysiology

