Related Experiment Video
Updated: Feb 22, 2026

Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
When does intraoperative 3D-imaging play a role in transpedicular C2 screw placement?
Cornelius Jacobs1, Philip P Roessler2, Sebastian Scheidt2
1Center for Musculoskeletal Surgery, Spine Surgery Unit, Charité - University Medicine Berlin, Germany; Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Germany.
Introduction:
The stabilization of an atlantoaxial (C1-C2) instability is demanding due to a complex atlantoaxial anatomy with proximity to the spinal cord, a variable run of the vertebral artery (VA) and narrow C2 pedicles. We perfomed the Goel & Harms fusion in combination with an intraoperative 3D imaging to ensure correct screw placement in the C2 pedicle. We hypothesized, that narrow C2 pedicles lead to a higher malposition rate of screws by perforation of the pedicle wall. The purpose of this study was to describe a certain pedicle size, under which the perforation rate rises.
Patients And Methods:
In this retrospective study, all patients (n=30) were operated in the Goel & Harms technique. The isthmus height and pedicle diameter of C2 were measured. The achieved screw position in C2 was evaluated according to Gertzbein & Robbin classification (GRGr).
Results:
A statistically significant correlation was found between the pedicles size (isthmus height/pedicle diameter) and the achieved GRGr for the right (p=0.002/p=0.03) and left side (p=0.018/p=0.008). The ROC analysis yielded a Cut Off value for the pedicle size to distinguish between an intact or perforated pedicle wall (GRGr 1 or ≥2). The Cut-Off value was identified for the isthmus height (right 6.1mm, left 5.4mm) and for the pedicle diameter (6.6mm both sides).
Conclusion:
The hypothesis, that narrow pedicles lead to a higher perforation rate of the pedicle wall, can be accepted. Pedicles of <6.6mm turned out to be a risk factor for a perforation of the pedicle wall (GRGr 2 or higher). Intraoperative 3D imaging is a feasible tool to confirm optimal screw position, which becomes even more important in cases with thin pedicles. The rising risk of VA injury in these cases support the additional use of navigation.