Background:
Serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) are used in the diagnosis and monitoring of plasma cell dyscrasias. IFE is considered the most sensitive method for the detection of monoclonal proteins (M-proteins), but it is not quantitative. The goal of this study was to establish the analytical sensitivity and diagnostic performance of SPE on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) β1-β2.
Methodology:
Patient sera with a previously identified M-protein (IgG, IgA or IgM) were serially diluted with a normal serum pool and electrophoresed on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) β1-β2. The SPE gels were individually interpreted by five independent observers and IFE was performed on selected samples. Limit of detection was determined as the lowest concentration of M-protein band visible on the gel. SPE diagnostic performance was evaluated against the "gold standard" IFE according CLSI EP12-A2 guidelines.
Results:
Detection limit was comparable among all M-proteins migrating in the gamma region, IgG-κ (0.18±0.08g/L; n=6), IgG-λ (0.36±0.25g/L; n=8), IgA-κ (0.40±0.13g/L; n=7), IgA-λ (0.37±0.23g/L; n=4), IgM-κ (0.47±0.20g/L; n=13) and IgM-λ (0.29±0.24g/L; n=6). Percentage agreement with IFE for IgG and IgA in the gamma region ranged from 65% to 100%, whereas IgM migrating in the gamma region and immunoglobulins co-migrating with alpha or beta globulins, showed poor (0-38%) agreement.
Conclusions:
This study evaluates the analytical sensitivity and diagnostic performance of SPE on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) β1-β2. There was acceptable agreement between SPE and IFE for IgG-κ/λ and IgA-κ/λ migrating in the gamma region, suggesting that repeating IFE for samples with these isotypes, when the previous IFE and second SPE are both negative, may not be necessary.
More Related Videos
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
07:58Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.