Related Experiment Video
Updated: Feb 22, 2026

Nanotopology of Cell Adhesion upon Variable-Angle Total Internal Reflection Fluorescence Microscopy VA-TIRFM
Published on: October 2, 2012
Refractive Index Imaging of Cells with Variable-Angle Near-Total Internal Reflection (TIR) Microscopy
Kevin P Bohannon1, Ronald W Holz1, Daniel Axelrod2
1Department of Pharmacology, University of Michigan Medical School, Ann Arbor, MI 48109, USA.
Abstract:
The refractive index in the interior of single cells affects the evanescent field depth in quantitative studies using total internal reflection (TIR) fluorescence, but often that index is not well known. We here present method to measure and spatially map the absolute index of refraction in a microscopic sample, by imaging a collimated light beam reflected from the substrate/buffer/cell interference at variable angles of incidence. Above the TIR critical angle (which is a strong function of refractive index), the reflection is 100%, but in the immediate sub-critical angle zone, the reflection intensity is a very strong ascending function of incidence angle. By analyzing the angular position of that edge at each location in the field of view, the local refractive index can be estimated. In addition, by analyzing the steepness of the edge, the distance-to-substrate can be determined. We apply the technique to liquid calibration samples, silica beads, cultured Chinese hamster ovary cells, and primary culture chromaffin cells. The optical technique suffers from decremented lateral resolution, scattering, and interference artifacts. However, it still provides reasonable results for both refractive index (~1.38) and for distance-to-substrate (~150 nm) for the cells, as well as a lateral resolution to about 1 µm.
More Related Videos
10:43Oligomerization Dynamics of Cell Surface Receptors in Living Cells by Total Internal Reflection Fluorescence Microscopy Combined with Number and Brightness Analysis
Published on: November 6, 2019
10:19Visualizing Adhesion Formation in Cells by Means of Advanced Spinning Disk-Total Internal Reflection Fluorescence Microscopy
Published on: January 21, 2019
Related Concept Videos
Total Internal Reflection Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...