Related Experiment Video
Updated: Feb 22, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Airflow Error Measurement Due to Pneumotachograph Mask Rim Leaks
Nicholas A May1, Ronald C Scherer1
1Department of Communication Sciences and Disorders, Bowling Green State University, 200 Health and Human Services Building (Ridge Street), Bowling Green, Ohio 43403.
Abstract:
Airflow during speech production is recorded using a pneumotachograph system wherein typically a mask is placed upon the face. Accurate measures of airflow require mask calibration and a complete seal of the mask rim to the face. Literature frequently cites mask rim leaks as causing flow measurement inaccuracies, but quantitative studies of the inaccuracies are needed. The purpose of this study was to determine the degree of inaccuracy of flow measurement using a Glottal Enterprises aerodynamic system for a variety of mask rim leak conditions. Air was pushed and pulled through the Glottal Enterprises mask system over a wide range of airflow with leaks simulated by small metal tubes of various cross-sectional areas placed between the mask rim and a face-like calibration mold. Two leak locations, single versus multiple leaks, and two different leak tube geometries were used. Results suggest that (1) as leak area increases, the amount of leak flow increases; (2) the amount of flow leak is relatively independent of location; (3) given equivalent leak areas, multiple leak locations provide less leak flow; and (4) quasi-elliptical tubes were more resistive to airflow than rectangular tubes. A general empirical equation was obtained that relates the leak flow between the mask rim and the face, the size of the leak region, and the amount of the upstream airflow toward the mask: Leak(cm3/s) = 0.33 × Area(cm2) × Flow(cm3/s) for the range of ±2000 cm3/s. This equation may provide researchers and clinicians with a tool for generalizing airflow leak effects.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pipe Flowrate Measurement: Problem Solving
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Errors in Taping

