Related Experiment Video
Updated: May 5, 2026

Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
Short-Wave Near-Infrared Linear Dichroism of Two-Dimensional Germanium Selenide
Xiaoting Wang1, Yongtao Li1, Le Huang1
1State Key Laboratory of Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences & College of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences , Beijing 100083, China.
Abstract:
Polarized detection has been brought into operation for optics applications in the visible band. Meanwhile, an advanced requirement in short-wave near-infrared (SW-NIR) (700-1100 nm) is proposed. Typical IV-VI chalcogenides-2D GeSe with anisotropic layered orthorhombic structure and narrow 1.1-1.2 eV band gap-potentially meets the demand. Here we report the unusual angle dependences of Raman spectra on high-quality GeSe crystals. The polarization-resolved absorption spectra (400-950 nm) and polarization-sensitive photodetectors (532, 638, and 808 nm) both exhibited well-reproducible cycles, distinct anisotropic features, and typical absorption ratios αy/αx ≈ 1.09 at 532 nm, 1.26 at 638 nm, and 3.02 at 808 nm (the dichroic ratio Ipy/Ipx ≈ 1.09 at 532 nm, 1.44 at 638 nm, 2.16 at 808 nm). Obviously, the polarized measurement for GeSe showed superior anisotropic response at around 808 nm within the SW-NIR band. Besides, the two testing methods have demonstrated the superior reliability for each other. For the layer dependence of linear dichroism, the GeSe samples with different thicknesses measured under both 638 and 808 nm lasers identify that the best results can be achieved at a moderate thickness about 8-16 nm. Overall, few-layer GeSe has capacity with the integrated SW-NIR optical applications for polarization detection.
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
UV–Vis Spectroscopy: Molecular Electronic Transitions
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....

