Related Experiment Video
Updated: Aug 14, 2026

Analyzing Protein Dynamics Using Hydrogen Exchange Mass Spectrometry
Published on: November 29, 2013
Suppressing allostery in epitope mapping experiments using millisecond hydrogen / deuterium exchange mass
Bin Deng1,2, Shaolong Zhu1,2, Andrew M Macklin1,2
1a Chemistry Department , York University , 4700 Keele Street, Toronto , ON , Canada.
Abstract:
Localization of the interface between the candidate antibody and its antigen target, commonly known as epitope mapping, is a critical component of the development of therapeutic monoclonal antibodies. With the recent availability of commercial automated systems, hydrogen / deuterium eXchange (HDX) is rapidly becoming the tool for mapping epitopes preferred by researchers in both industry and academia. However, this approach has a significant drawback in that it can be confounded by 'allosteric' structural and dynamic changes that result from the interaction, but occur far from the point(s) of contact. Here, we introduce a 'kinetic' millisecond HDX workflow that suppresses allosteric effects in epitope mapping experiments. The approach employs a previously introduced microfluidic apparatus that enables millisecond HDX labeling times with on-chip pepsin digestion and electrospray ionization. The 'kinetic' workflow also differs from conventional HDX-based epitope mapping in that the antibody is introduced to the antigen at the onset of HDX labeling. Using myoglobin / anti-myoglobin as a model system, we demonstrate that at short 'kinetic' workflow labeling times (i.e., 200 ms), the HDX signal is already fully developed at the 'true' epitope, but is still largely below the significance threshold at allosteric sites. Identification of the 'true' epitope is supported by computational docking predictions and allostery modeling using the rigidity transmission allostery algorithm.
More Related Videos
11:32A Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Platform for Investigating Peptide Biosynthetic Enzymes
Published on: May 4, 2020
08:40Millisecond Hydrogen/Deuterium-Exchange Mass Spectrometry for the Study of Alpha-Synuclein Structural Dynamics Under Physiological Conditions
Published on: June 23, 2022
Related Concept Videos
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...