Related Experiment Video
Updated: Feb 22, 2026
![PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F57243.jpg&w=3840&q=50)
PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke
Published on: June 14, 2018
Test-Retest Reliability of the SERT Imaging Agent 11C-HOMADAM in Healthy Humans
Vikram Adhikarla1, Boadie W Dunlop2, Nashwa Jarkas1
1Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia; and.
Abstract:
The aim of this study was to measure the test-retest reliability of 11C-N,N-dimethyl-2-(2'-amino-4'-hydroxymethylphenylthio)benzylamine (11C-HOMADAM) imaging of serotonin transporter (SERT) density in healthy control subjects. Methods: Two female and 2 male volunteers participated in the study, with each undergoing three 90-min 11C-HOMADAM PET scans. Time-activity curves were derived from SERT-rich structures and fit to 2 models: a simplified reference tissue model and a multilinear graphical model. Binding potential, the ratio of specifically bound uptake to nondisplaceable uptake at equilibrium, was calculated from the model parameter estimates. Ninety-five percent confidence intervals and the intraclass correlation coefficient (ICC) were calculated and adjusted for repeated measures. Results: The ICC values ranged from -0.13 in the dorsal raphe to 0.88 in the caudate nucleus. The highest average ICC values were in the striatum, but other regions were sensitive to measurement outliers. Conclusion: Good-to-excellent test-retest reliability was observed for SERT binding in the striatum. The dorsal raphe ICC value was sensitive to a measurement outlier. 11C-HOMADAM binding potential calculated from the simplified reference tissue model and the multilinear graphical model were robust and in good agreement.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:52Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...