The effect of an increased pulse width on the pattern of motor response (unilateral versus bilateral) during the Tsui
Paul Zakus1,2, Ricardo Bittencourt3, Kristi Downey3
1Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, Toronto, ON, Canada. pgzakus@gmail.com.
Background And Objectives:
The typical response to the Tsui test performed via an epidural catheter placed in the lumbar area is the unilateral motor response of the lower limbs. Studies show that longer pulse widths can stimulate peripheral nerves at a lower threshold current from a farther distance. Therefore, we designed a study to test the hypothesis that epidural catheter stimulation with a 1.0-msec pulse width would increase the incidence of bilateral motor response in parturients when compared with stimulation with a 0.1-msec pulse width.
Methods:
Parturients requesting epidural analgesia were recruited into this randomized crossover study. The Tsui test was performed at both pulse widths before and five minutes after an epidural test dose of 2% lidocaine 3 mL. The primary outcome was the motor response pattern (either unilateral or bilateral) to the epidural catheter stimulation at baseline.
Results:
Twenty women were recruited for the study, which was stopped early due to futility. The rates of unilateral motor response in the 0.1-msec (18/20) and the 1-msec (18/20) group were both 90% (rate difference, 0%; 95% confidence interval [CI], -0.3 to 0.3; P = 1.0). The mean (SD) current required to elicit a motor response at baseline was 4.2 (2.6) mA in the 0.1-msec group and 1.7 (1.1) mA in the 1-msec group (mean difference, 2.5; 95% CI, 1.2 to 2.3; P < 0.001).
Conclusions:
The motor response pattern following the stimulation of a lumbar epidural catheter with pulse widths of 0.1 msec or 1 msec is similar and typically unilateral. The threshold current is lower with the 1-msec pulse width stimulus.
Trial Registration:
www.clinicaltrials.gov, NCT02762149. Registered 2 May 2016.