Related Experiment Video
Updated: Feb 22, 2026

Applying Hyperspectral Reflectance Imaging to Investigate the Palettes and the Techniques of Painters
Published on: June 18, 2021
Accurate representation of interference colours (Michel-Lévy chart): from rendering to image colour correction
S A Linge Johnsen1, J Bollmann1, H W Lee2
1Department of Earth Sciences, University of Toronto, Toronto, Ontario, Canada.
Abstract:
Here a work flow towards an accurate representation of interference colours (Michel-Lévy chart) digitally captured on a polarised light microscope using dry and oil immersion objectives is presented. The work flow includes accurate rendering of interference colours considering the colour temperature of the light source of the microscope and chromatic adaptation to white points of RGB colour spaces as well as the colour correction of the camera using readily available colour targets. The quality of different colour correction profiles was tested independently on an IT8.7/1 target. The best performing profile was using the XYZ cLUT algorithm and it revealed a ΔE00 of 1.9 (6.4 no profile) at 5× and 1.1 (8.4 no profile) at 100× magnification, respectively. The overall performance of the workflow was tested by comparing rendered interference colours with colour-corrected images of a quartz wedge captured over a retardation range from 80-2500 nm at 5× magnification. Uncorrected images of the quartz wedge in sRGB colour space revealed a mean ΔE00 of 12.3, which could be reduced to a mean of 4.9 by applying a camera correction profile based on an IT8.7/1 target and the Matrix only algorithm (ΔE00 < 1.0 signifies colour differences imperceptible by the human eye). ΔE00 varied significantly over the retardation range of 80-2500 nm of the quartz wedge, but the reasons for this variation is not well understood and the quality of colour correction might be further improved in future by using custom made colour targets specifically designed for the analysis of high-order interference colours.
Related Concept Videos
Interference and Diffraction
Color Vision
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Flame Photometry: Lab
Flame Photometry: Overview