Related Experiment Video
Updated: Feb 22, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Efficacy of constant load verification testing to confirm VO2 max attainment
Todd A Astorino1, Jamie DeRevere1,2
1Department of Kinesiology, CSU-San Marcos, San Marcos, CA, USA.
Abstract:
Although maximal oxygen uptake (VO2 max) has been measured for almost 100 years, it is unknown when 'true' VO2 max is attained. Primary (the VO2 plateau) and secondary criteria are used to confirm VO2 max incidence, but frequency of the VO2 plateau varies, and secondary criteria are relatively invalid. The verification test (VER) seems to elicit similar estimates of VO2 max versus the incremental value (INC), yet existing data are limited by small populations and use of inadequate criteria to confirm 'true' VO2 max. We investigated the efficacy of VER by analysing data from 109 participants who underwent INC followed by VER at 105% or 110% of peak power output (PPO). Differences in VO2 max between VER and INC were analysed, and intraclass correlation coefficient (ICC), standard error of the mean (SEM) and minimum difference (MD) were computed. Results showed that VO2 max was significantly higher (2%, P<0·05) in INC versus VER, VO2 max was highly related between protocols (ICC = 0·99) and SEM and MD were low. However, 11% of participants did not reveal 'true' VO2 max as the verification value was higher than INC by 3·0% - 3·3%. Fitness level altered the difference in VO2 max between INC and VER in study one, as lower fitness individuals showed a larger difference in VO2 max between protocols, although gender did not affect the difference in VO2 max between protocols. Our data show that VER does not verify 'true' VO2 max in all individuals, which may be related to their fitness level.
More Related Videos
Related Concept Videos
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes

