Preferred Compression Threshold and Release Time in Quiet and Noisy Conditions for Elderly Korean Hearing Aid Users
Woojae Han1, Junghak Lee2, Jinsook Kim1
1Division of Speech Pathology and Audiology, Research Institute of Audiology and Speech Pathology, College of Natural Sciences, Hallym University, Chuncheon, Korea.
Background And Objectives:
Listeners with sensorineural hearing loss want to compensate for their narrow dynamic range from appropriate compression functions of hearing aids. The present study aimed to determine which compression threshold and release time of nonlinear hearing aids might affect speech recognition and speech quality judgments.
Subjects And Methods:
Ten elderly listeners with symmetrical moderate-to-severe sensorineural hearing loss participated in the study. To compare two compression threshold (31 dB SPL vs. 61 dB SPL) and two release time (50 ms vs. 500 ms) conditions, subjects' speech recognition was measured using the Korean version of the Hearing in Noise Test in both quiet and noisy situations. All subjects were also asked to rate the degree of speech quality in terms of loudness, sharpness, clarity, and background noise immediately after completing the speech recognition test.
Results:
Although no significant difference emerged in speech recognition thresholds between the two compression thresholds in the quiet situation, the compression threshold of 31 dB SPL showed a lower (or better) signal-to-noise ratio of speech recognition compared to that of 61 dB SPL. The release times of 50 and 500 ms did not statistically differ in both quiet and noisy situations. Subjective categories were found to be louder and clearer in the 50 ms release time for quiet and noisy, respectively.
Conclusions:
We expect that these patterns of current results will apply for better-fitting protocol of elderly Korean hearing aid users.
More Related Videos
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Hearing
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...