Related Experiment Video
Updated: Feb 22, 2026

Reduced Complications after Arterial Reconnection in a Rat Model of Orthotopic Liver Transplantation
Published on: November 7, 2020
Venous anastomosis using a non-penetrating vascular closure system in orthotopic liver transplantation
Yuan Wang1, Zhao Xin1, Bing Pan1
1Department of Hepatobiliary Surgery, Beijing Chaoyang Hospital Affiliated to Capital Medical University, Beijing, China.
Background:
A non-penetrating vessel closure system (VCS-AnastoClip® ) may facilitate vascular anastomosis. The purpose of this study is to explore the utilization of a non-penetrating VCS in orthotopic liver transplantation (OLT).
Methods:
From January 2015 to February 2017, patients who underwent OLT were divided into two groups, ie, those who underwent non-penetrating VCS application for inferior vena cava (IVC) and portal vein (PV) reconstructions and those who underwent hand sewing for these purposes. Clinical data, venous anastomotic times, anhepatic phases, and the recovery of liver function were compared between the groups.
Results:
One hundred and fifteen patients underwent OLT (63 in the VCS group and 52 in the suture group). No differences between the two groups were observed in the baseline characteristics. The venous anastomotic time and anhepatic phase in the VCS group were significantly shorter than those in the suture group (P < .01). The alanine transaminase and total bilirubin levels in the VCS group were comparable to those in the suture group (P = .39 and P = .06, respectively). The complication, mortality, and patency rates of the PV reconstructions did not differ significantly between the two groups.
Conclusions:
In OLT, the reconstruction of the PV and IVC with a non-penetrating VCS system is a safe alternative method that has the advantage of shortening the anastomotic time and the anhepatic phase compared to the results of conventional hand suturing. However, the use of this VCS system had no influence on the recovery of graft function.