Quadruplex PCR assay for identification of Corynebacterium pseudotuberculosis differentiating biovar Ovis and Equi
Sintia Almeida1, Elaine M S Dorneles2, Carlos Diniz3,4
1Instituto de Ciências Biológicas, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil. sintiaalmeida@gmail.com.
Background:
Corynebacterium pseudotuberculosis is classified into two biovars, nitrate-negative biovar Ovis which is the etiologic agent of caseous lymphadenitis in small ruminants and nitrate-positive biovar Equi, which causes abscesses and ulcerative lymphangitis in equines. The aim of this study was to develop a quadruplex PCR assay that would allow simultaneous detection and biovar-typing of C. pseudotuberculosis.
Methods:
In the present study, genomes of C. pseudotuberculosis strains were used to identify the genes involved in the nitrate reduction pathway to improve a species identification three-primer multiplex PCR assay. The nitrate reductase gene (narG) was included in the PCR assay along with the 16S, rpoB and pld genes to enhance the diagnosis of the multiplex PCR at biovar level.
Results:
A novel quadruplex PCR assay for C. pseudotuberculosis species and biovar identification was developed. The results of the quadruplex PCR of 348 strains, 346 previously well-characterized clinical isolates of C. pseudotuberculosis from different hosts (goats, sheep, horse, cattle, buffalo, llamas and humans), the vaccine strain 1002 and the type strain ATCC 19410T, were compared to the results of nitrate reductase identification by biochemical test. The McNemar's Chi-squared test used to compare the two methods used for C. pseudotuberculosis biovar identification showed no significant difference (P = 0.75) [95% CI for odds ratio (0.16-6.14)] between the quadruplex PCR and the nitrate biochemical test. Concordant results were observed for 97.13% (338 / 348) of the tested strains and the kappa value was 0.94 [95% CI (0.90-0.98)].
Conclusions:
The ability of the quadruplex assay to discriminate between C. pseudotuberculosis biovar Ovis and Equi strains enhances its usefulness in the clinical microbiology laboratory.
More Related Videos
05:34Author Spotlight: Development of an Enhanced Protocol for Rapid and Accurate Isolation of Campylobacter from Food Products
Published on: February 23, 2024
11:09Multiplex Detection of Bacteria in Complex Clinical and Environmental Samples using Oligonucleotide-coupled Fluorescent Microspheres
Published on: October 23, 2011
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
PCR