Related Experiment Video
Updated: Feb 22, 2026

An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
Causes, consequences and management of sample hemolysis in the clinical laboratory
Laura Heireman1, Pieter Van Geel2, Lorenz Musger1
1Department of Laboratory Medicine, Ziekenhuis Netwerk Antwerpen, Antwerp, Belgium.
Abstract:
Preanalytical hemolysis of blood samples is a common problem in medical practice, especially in emergency departments. Several potential influences on sample hemolysis have been investigated, including sampling techniques, centrifugation and sample transport. In particular, the use of intravenous catheters and the vacuum sampling technique have often been demonstrated to provoke hemolysis. Other factors playing a role include the use of inappropriate puncture sites, complicated blood sampling, prolonged tourniquet application, underfilling of tubes and excessive shaking of specimens. Training of phlebotomists can play a pivotal role in overcoming these issues. A sample may also undergo hemolysis at the point of centrifugation, more specifically when centrifugation lasts too long or is done repeatedly. Pneumatic tube system (PTS)-transported samples tend to be more strongly affected by hemolysis compared to hand-carried ones, though whether this difference is clinically relevant remains questionable. The velocity at which the sample moves, the distance it covers and the shock forces it sustains all determine to what extent hemolysis occurs during PTS transport. The use of cushion inserts in the carrier to stabilize the samples and the presence of a gel separator in the transported serum tubes may prevent PTS-induced hemolysis. Finally, there is considerable variation between patients in the extent to which samples are prone to hemolysis. Sample hemolysis leads to unreliable laboratory results, delayed diagnosis and patients suffering avoidable discomfort. Specifically, hemolysis may interfere with laboratory results due to release of intracellular components, dilution effects, proteolysis and interference with analytical techniques. There is ongoing debate about how laboratories should deal with results altered by hemolysis. Laboratory specialists should clearly communicate with the ordering clinicians in order to make an informed decision about how to interpret hemolysis-affected analytical results. This review looks into current evidence concerning the causes and consequences of in vitro hemolysis, and aims to explain how to deal with it.
More Related Videos
11:12Ex Vivo Red Blood Cell Hemolysis Assay for the Evaluation of pH-responsive Endosomolytic Agents for Cytosolic Delivery of Biomacromolecular Drugs
Published on: March 9, 2013
07:24A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
Related Concept Videos
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Hypersensitivity Reactions: Cytolytic Reactions
Disorders of Erythrocytes
Erythrocyte disorders can be broadly categorized into two main types: anemic and polycythemic conditions.
A low oxygen-carrying capacity of the blood due to the loss, lower production, or destruction of erythrocytes is termed anemia. Hemorrhagic anemia, for example, occurs when bleeding from an external wound or internal ulcer reduces erythrocyte counts.
On the other...
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Rh Blood Group
Errors occurring during blood pressure monitoring
Several factors...