Related Experiment Video
Updated: Feb 22, 2026

Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
Survey of urinary nickel in peritoneal dialysis patients
Ya-Ching Huang1,2, Hsiao-Chen Ning1,2, Shang-Syuan Chen1
1Department of Laboratory Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan.
Abstract:
This study surveyed urinary nickel concentrations in peritoneal dialysis (PD) patients, and analyzed the association of urinary nickel concentrations with clinical outcomes and inflammatory biomarkers. In total, 50 PD patients and 50 healthy controls were recruited for this study. All participants were examined for the presence of toxic trace elements (antimony, arsenic, bismuth, cadmium, copper, manganese, mercury, nickel, lead, tellurium, thallium and zinc) in their urine by using inductively coupled plasma mass spectrometry (ICP-MS). It was found that PD patients demonstrated higher urinary nickel concentrations than healthy controls (6.1±3.5 versus 2.8±1.4 μg/L, P<0.001). There were 24 (48.0%) PD patients with normal urinary nickel concentrations, and 26 (52.0%) PD patients with high urinary nickel concentrations. The PD patients with high urinary nickel concentrations demonstrated higher log serum levels of high sensitivity C-reactive protein (0.4±0.5 versus 0.1±0.5 mg/L, P=0.046) than patients with normal urinary nickel concentrations. Furthermore, patients with high urinary nickel concentrations exhibited higher levels of cadmium (1.3±0.9 versus 0.6±0.5 μg/L, P<0.001), copper (7.7±5.7 versus 3.3±1.4 μg/L, P<0.001) and manganese (0.9±1.1 versus 0.4±0.4 μg/L, P=0.023) than patients with normal urinary nickel concentrations. Nevertheless, there were no significant differences in the clinical outcomes between PD patients with high and normal urinary nickel concentrations (P>0.05). Thus, it is concluded that approximately half of the patients undergoing PD had elevated urinary nickel levels, and these patients also had elevated serum levels of high sensitivity C-reactive protein. Nevertheless, no other real correlations were discovered including no impact on patient outcome. Further studies are warranted.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
07:45Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
Published on: February 9, 2021
Related Concept Videos
Peritoneal Dialysis III: Nursing Management
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Nephrotic Syndrome II : Assessment and Medical Management
Nursing Assessment of the Genitourinary System II: Inspection and Palpation
Acute Kidney Injury IV: Diagnostic Studies and Prevention