Related Experiment Video
Updated: Feb 22, 2026

Electrospinning of Photocatalytic Electrodes for Dye-sensitized Solar Cells
Published on: June 28, 2017
New Titanium Dioxide-Based Heterojunction Nanohybrid for Highly Selective Photoelectrochemical-Electrochemical
Muthuchamy Nallal1, Gopalan Anantha Iyengar1, Kwang Pill-Lee1
1Department of Chemistry Education, ‡Research Institute of Advanced Energy Technology, and §Department of Nanoscience and Nanotechnology, Kyungpook National University , Daegu 41566, South Korea.
Abstract:
A new titanium dioxide (TiO2)-based heterojunction nanohybrid (HJNH) composed of TiO2, graphene (G), poly[3-aminophenylboronic acid] (PAPBA), and gold nanoparticles (Au NPs) was synthesized and designated as TiO2(G) NW@PAPBA-Au HJNH. The TiO2(G) NW@PAPBA-Au HJNH possesses dual-mode signal photoelectrochemical (PEC) and electrochemical transduction capabilities to sense glucose and glycated hemoglobin (HbA1c) independently. The synthesis of the HJNH material involved two sequential stages: (i) simple electrospinning synthesis of G-embedded TiO2 nanowires [TiO2(G) NWs] and (ii) one-step synthesis of Au NP-dispersed PAPBA nanocomposite (NC) in the presence of TiO2(G) NWs. The as-synthesized TiO2(G) NW@PAPBA-Au HJNH was characterized by field emission scanning electron microscopy, field emission transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, Fourier transform infrared, thermogravimetric analysis, and UV-visible diffuse reflectance spectroscopy. A PEC platform was developed with TiO2(G) NW@PAPBA-Au HJNH for the selective detection of glucose without any enzyme auxiliary. The PEC glucose sensor presents an acceptable linear range (from 0.5 to 28 mM), good sensitivity (549.58 μA mM-1 cm-2), and low detection limit (0.11 mM), which are suited for diabetes glucose monitoring. Besides, the boronic acid groups in PAPBA were utilized as a host to capture HbA1c. We fabricated the electrochemical HbA1c sensor based on monitoring the electrocatalytic reduction current of hydrogen peroxide produced by HbA1c tethered to the sensor probe. The amperometric electrochemical sensor for HbA1c exhibited linear responses to HbA1c levels from 2.0 to 10% (with a detection limit of 0.17%). Notably, the performances of the fabricated glucose and HbA1c sensors are superior in the dual-signal transduction modes as compared to the literature, suggesting the significance of the newly designed bifunctional TiO2(G) NW@PAPBA-Au HJNH.
More Related Videos
12:47Preparation and Use of Photocatalytically Active Segmented Ag|ZnO and Coaxial TiO2-Ag Nanowires Made by Templated Electrodeposition
Published on: May 2, 2014
08:34A Dual-Functional Electroactive Filter Towards Simultaneously SbIII Oxidation and Sequestration