Related Experiment Video
Updated: Feb 22, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different
Adarsh Ghosh1, Tulika Singh1, Veenu Singla1
11 Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Sector 12, Chandigarh 160012, India.
Different software programs produce significantly different apparent diffusion coefficient (ADC) values. Standardization of ADC postprocessing algorithms is crucial for accurate tissue characterization in MRI.
Area of Science:
- Radiology and Medical Imaging
- Biomedical Engineering
- Quantitative MRI
Background:
- Apparent diffusion coefficient (ADC) maps are vital for quantitative MRI analysis.
- Current ADC map generation relies on vendor-specific software, limiting standardization.
- Open-source software offers alternatives for image postprocessing and parametric map generation.
Purpose of the Study:
- To assess the reproducibility of absolute ADC values derived from different postprocessing software.
- To compare ADC values generated by in-line vendor software versus external postprocessing tools.
Main Methods:
- Diffusion-weighted (DW) images were acquired using a 1.5-T MRI scanner with three b values.
- ADC maps were generated using both the MRI vendor's in-line software and separate postprocessing software.
- Comparison involved regions of interest (ROIs) analyzed with statistical tests and graphical methods (Bland-Altman, Passing-Bablok).
Main Results:
- A statistically significant difference was observed in mean ADC values across different postprocessing software packages.
- Variability in ADC values was evident even when using identical baseline trace DW images.
Conclusions:
- The choice of postprocessing software significantly impacts absolute ADC values.
- Standardization of postprocessing algorithms is essential for reliable ADC quantification in histology.
- This standardization is particularly important for vendor-neutral archiving and cross-platform data analysis.