Related Experiment Video
Updated: Feb 22, 2026

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Double Biocatalysis Signal Amplification Glucose Biosensor Based on Porous Graphene
Yaping He1, Jianbin Zheng2, Bini Wang3
1School of Chemical Engineering, Xi'an University, Xi'an 710065, Shaanxi, China. hejin04c@126.com.
Abstract:
Controllable preparation of nanopores to promote the performance of electrochemical biosensing interfaces has become one of the researching frontiers in biosensing. A double biocatalysis signal amplification of glucose biosensor for the study of electrochemical behaviors of glucose oxidase (GOx) was proposed by using horseradish peroxidase biosynthesized porous graphene (PGR) as the platform for the biocatalytic deposition of gold nanoparticles (AuNPs). The biosensor showed a linear range from 0.25 to 27.5 μM with a detection limit of 0.05 μM (S/N = 3) towards glucose. Furthermore, the proposed AuNPs/GOx-PGR modified glassy carbon electrode (AuNPs/GOx-PGR/GCE) achieved direct electron transfer of GOx.