Related Experiment Video
Updated: Feb 22, 2026

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
Implementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and
N M deSouza1, J M Winfield2, J C Waterton3
1CRUK Cancer Imaging Centre, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Downs Road, Surrey, SM2 5PT, UK. Nandita.Desouza@icr.ac.uk.
Standardizing diffusion-weighted MRI acquisition and analysis is crucial for comparing apparent diffusion coefficient (ADC) values across institutions. This harmonization is essential for validating ADC as a reliable biomarker in multicenter oncology trials.
Area of Science:
- Medical Imaging
- Oncology
- Biomarker Development
Background:
- Diffusion-weighted MRI (DW-MRI) is valuable for tumor detection, staging, and response assessment in body imaging.
- Quantitative evaluation of apparent diffusion coefficient (ADC) is necessary for prognosis and treatment response monitoring.
- Current variability in DW-MRI acquisition and analysis methods hinders multicenter trial implementation and ADC biomarker utility.
Purpose of the Study:
- To review factors contributing to ADC variability in diffusion-weighted MRI.
- To discuss hardware, software, and quality control measures for standardized protocols.
- To outline data handling and procedural considerations for multicenter trials.
Main Methods:
- Review of technical and biological performance factors affecting ADC values.
- Discussion of multi-vendor platform standardization challenges.
- Consideration of data collection, archiving, analysis, and quality assurance processes.
Main Results:
- Variability in acquisition and analysis methodologies prevents comparability of ADC values across centers.
- Standardized protocols are needed to address hardware and software considerations for multi-vendor platforms.
- Implementing quality assurance and control is vital for reproducible results.
Conclusions:
- Standardized acquisition and analysis enable quantification of imaging biomarkers in multicenter trials.
- Establishing measurement precision within a multicenter context is essential for biomarker validation.
- A traceable data repository promotes further research and development of ADC as a biomarker.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...