Related Experiment Video
Updated: Feb 22, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Influence of critical closing pressure on systemic vascular resistance and total arterial compliance: A clinical
Denis Chemla1, Edmund M T Lau2, Philippe Hervé3
1Service de physiologie, hôpital de Bicêtre, hôpitaux universitaires Paris-Sud, 94275 Le Kremlin-Bicêtre, France; Université Paris-Sud, 94275 Le Kremlin-Bicêtre, France; Inserm UMR_S999, LabEx Lermit, centre chirurgical Marie-Lannelongue, 92350 Le Plessis Robinson, France.
Background:
Systemic vascular resistance (SVR) and total arterial compliance (TAC) modulate systemic arterial load, and their product is the time constant (Tau) of the Windkessel. Previous studies have assumed that aortic pressure decays towards a pressure asymptote (P∞) close to 0mmHg, as right atrial pressure is considered the outflow pressure. Using these assumptions, aortic Tau values of ∼1.5seconds have been documented. However, a zero P∞ may not be physiological because of the high critical closing pressure previously documented in vivo.
Aims:
To calculate precisely the Tau and P∞ of the Windkessel, and to determine the implications for the indices of systemic arterial load.
Methods:
Aortic pressure decay was analysed using high-fidelity recordings in 16 subjects. Tau was calculated assuming P∞=0mmHg, and by two methods that make no assumptions regarding P∞ (the derivative and best-fit methods).
Results:
Assuming P∞=0mmHg, we documented a Tau value of 1372±308ms, with only 29% of Windkessel function manifested by end-diastole. In contrast, Tau values of 306±109 and 353±106ms were found from the derivative and best-fit methods, with P∞ values of 75±12 and 71±12mmHg, and with ∼80% completion of Windkessel function. The "effective" resistance and compliance were ∼70% and ∼40% less than SVR and TAC (area method), respectively.
Conclusion:
We did not challenge the Windkessel model, but rather the estimation technique of model variables (Tau, SVR, TAC) that assumes P∞=0. The study favoured a shorter Tau of the Windkessel and a higher P∞ compared with previous studies. This calls for a reappraisal of the quantification of systemic arterial load.
More Related Videos
Related Concept Videos
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)

