Related Experiment Video
Updated: Feb 22, 2026

Rapid, Safe, and Simple Manual Bedside Nucleic Acid Extraction for the Detection of Virus in Whole Blood Samples
Published on: June 30, 2018
Ebola Virus Inactivation by Detergents Is Annulled in Serum
Jeroen J A van Kampen1, Andrei Tintu2, Henk Russcher2
1Department of Viroscience.
Background:
Treatment of blood samples from hemorrhagic fever virus (HFV)-infected patients with 0.1% detergents has been recommended for virus inactivation and subsequent safe laboratory testing. However, data on virus inactivation by this procedure are lacking. Here we show the effect of this procedure on diagnostic test results and infectious Ebola virus (EBOV) titers.
Methods:
Serum and whole-blood samples were treated with 0.1% or 1% sodium dodecyl sulfate (SDS) or 0.1% Triton X-100 and assayed for clinical chemistry and malaria antigen detection. Infectious EBOV titers were determined in SDS-treated plasma and whole blood from EBOV-infected nonhuman primates (NHPs). Infectious titers of EBOV or herpes simplex virus type 1 (HSV-1) in detergents-treated cell culture medium containing various serum concentrations were determined.
Results:
Laboratory test results were not affected by 0.1% detergent treatment of blood samples, in contrast with 1% SDS treatment. However, 0.1% detergent treatment did not inactivate EBOV in blood samples from infected NHPs. Experiments with cell culture medium showed that virus inactivation by detergents is annulled at physiological serum concentrations.
Conclusions:
Treatment of blood samples with 0.1% SDS or Triton X-100 does not inactivate EBOV. Inactivation protocols for HFV should be validated with serum and whole blood.