Related Experiment Video
Updated: Feb 22, 2026

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
Self-expandable metal stent for malignant esophagorespiratory fistula: predictive factors associated with clinical
Maria Sylvia Ierardi Ribeiro1, Bruno da Costa Martins1, Marcelo Simas de Lima1
1Department of Gastroenterology, Cancer Institute of Sao Paulo, University of Sao Paulo, Sao Paulo, Brazil.
Background And Aims:
Malignant esophagorespiratory fistulas (MERFs) usually are managed by the placement of self-expandable metal stents (SEMSs) but with conflicting results. This study aimed to identify risk factors associated with clinical failure after SEMS placement for the treatment of MERFs.
Methods:
This was a retrospective analysis of a prospectively maintained database used at a tertiary-care cancer hospital, with patients treated with SEMS placement for MERFs between January 2009 and February 2016. Logistic regression was used to identify predictive factors for clinical outcomes and to estimate the odds ratio (OR) and the 95% confidence interval (CI). The Kaplan-Meier method was used for survival analysis, and comparisons were made by using the log-rank test.
Results:
A total of 71 patients (55 male, mean age 59 years) were included in the study, and 70 were considered for the final analysis (1 failed stent insertion). Clinical failure occurred in 44% of patients. An Eastern Cooperative Oncology Group (ECOG) performance status of 3 or 4 and fistula development during esophageal cancer treatment were associated with an increased risk of clinical failure. ECOG status of 3 or 4, pulmonary infection at the time of SEMS placement, and prior radiation therapy were predictive factors associated with lower overall survival. Dysphagia scores improved significantly 15 days after stent insertion. The overall stent-related adverse event rate was 30%. Stent migration and occlusion caused by tumor overgrowth were the most common adverse events.
Conclusion:
SEMS placement is a reasonable treatment option for MERFs; however, ECOG status of 3 or 4 and fistula development during esophageal cancer treatment may be independent predictors of clinical failure after stent placement.
Related Concept Videos
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Barrett Esophagus-I: Introduction
This constant acid exposure transforms the esophagus's pink mucosal lining (stratified squamous epithelium) into a type of lining more...

