Related Experiment Video
Updated: Feb 21, 2026

Using a Thermal Camera to Measure Heat Loss Through Bird Feather Coats
Published on: June 17, 2020
Physical and computer-based modeling in internal temperature reconstruction by the method of passive acoustic
A A Anosov1, P V Subochev2, A D Mansfeld2
1Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation, 2-4 Bolshaya Pirogovskaya st., 119991 Moscow, Russia; Kotel'nikov Institute of Radio Engineering and Electronics of the Russian Academy of Sciences, Mokhovaya 11-7, Moscow 125009, Russia.
Abstract:
The purpose of this work was to investigate experimentally the capacity of passive acoustic thermometry (PAT) for the reconstruction of 1D, time-variable distributions of the internal temperature. Because in the PAT a noise signal is measured, a considerable integration time (about one minute) is required to attain an acceptable error level (0.5-1K). To optimize the time, an algorithm was proposed to take account of the fact that the temperature satisfied the heat equation. The problem was reduced to that of determining two parameters (initial temperature and thermal diffusivity) of the object under study. The desired parameters were considered constant and were not determined anew after each measurement; instead, their values were refined using all the previous measurements. The proposed algorithm was tested experimentally (where the temperature was reconstructed in a model object, a slab of polytetrafluoroethylene) and investigated by means of computer modeling. The duration of one measurement was about 5.5s. As a result, an error of the temperature reconstruction of about 0.5K, acceptable for medical applications, was attained after 30-60s (depending on the depth) from the beginning of the measurements. After that, temperature distributions can be reconstructed after each measurement without loss of the reconstruction accuracy. The proposed method can be used to control the temperature under a local hyperthermia, lasting 1 min and more, of the human body.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

