Is mesocardia with left-sided caval vein draining to coronary sinus a contraindication for a percutaneous pulmonary
Marinos Kantzis1, Christoph M Happel1, Nikolaus A Haas1
11Centre for Congenital Heart Disease,Heart and Diabetes Centre,Bad Oeynhausen,Ruhr University of Bochum,North Rhine Westphalia,Germany.
Abstract:
Introduction Although the right jugular vein approach for percutaneous pulmonary valve implantation is well described, there are no reports that describe a percutaneous pulmonary valve implantation through a left superior caval vein to coronary sinus pathway. Case A 14-year-old female with tetralogy of Fallot, mesocardia, left superior caval vein draining into the coronary sinus, and hemiazygos continuation of the inferior caval vein underwent ventricular septal defect closure, with homograft insertion from the right ventricle to the pulmonary artery, patch augmentation of the left pulmonary artery, and creation of an atrial communication. Thereafter followed numerous catheterisations and interventions with stent implantation for stenosis of the left pulmonary artery and the homograft, as did device closure of the atrial communication. When she was a 12-year-old, the indications for a percutaneous pulmonary valve implantation were fulfilled and she underwent implantation of a 22 mm Melody® valve through the left superior caval vein. The extra-stiff exchange wire was pre-formed into a "U-spiral"-type configuration, according to the underlying anatomy, in order to provide a smooth route for the delivery of stents, to create the landing zone, and for the implantation of the Melody "ensemble". The procedure was performed under deep sedation according to our standard protocol. The duration of the procedure was 172 min and the radiation time was 24.9 min.
Conclusion:
On the basis of this unique experience, percutaneous pulmonary valve implantation is safe and feasible even in patients with unusual anatomy. Crucial is the "U-spiral" shaped configuration of the guide wire.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Cardiac Catheterization III: Left Heart Catheterization
Mitral Stenosis III: Medical Management