Related Experiment Video
Updated: Feb 21, 2026

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
Re-excision rates after breast conserving surgery following the 2014 SSO-ASTRO guidelines
Alicia A Heelan Gladden1, Sharon Sams2, Ana Gleisner1
1University of Colorado School of Medicine, Department of Surgery, Aurora, CO, USA.
Background:
In 2014, SSO-ASTRO published guidelines which recommended "no ink on tumor" as adequate margins for patients undergoing breast conservation for invasive breast cancer. In 2016, new SSO-ASTRO-ASCO guidelines recommended 2 mm margins for DCIS. We evaluated whether these guidelines affected re-excision rates at our institution.
Methods:
Patients treated with breast conservation surgery from January 1, 2010-March 1, 2016 were identified. Re-excision rates, tumor characteristics, and presence of residual disease were recorded. The 2016 guidelines were retrospectively applied to the same cohort and expected re-excision rates calculated.
Results:
Re-excision rates did not significantly decline before and after 2014 guideline adoption (11.9% before, 10.9% after; p = 0.65) or when the 2016 guidelines were retrospectively applied (8.4%; p = 0.10).
Conclusions:
The 2014 and 2016 guidelines had minimal impact on our re-excision rates, as most re-excisions were done for DCIS and 2016 guidelines supported our prior institutional practices of 2 mm margins for these patients.